Overview
Perkins Engine Company is a world-famous engine corporation. It has a glorious engine production sale history. Founded in 1932 by British entrepreneur Frank Perkins in Britain, Perkins-Rolls-Royce engine, has applied the latest electronic fuel injection control system. It has small volume, light weight, reliable performance and low consumption. The exhaust emission has achieved German TALUFT standard, American EPA Tier 3 standard and EU-Ⅲstandard.
The SCOPE POWER-PERKINS generator set, uses an original PERKINS engine from Perkins Engine (UK) Company. It also includes an alternator, base frame, connecting flange, fuel tank, control system, etc.
Alternator
The diesel generator set powered by PERKINS engine can be coupled with the SCOPE POWER series A.C. synchronous brushless alternator (a new style we designed, with updated international technology). It can also be matched with a STAMFORD, LEROY SOMER or MARATHON alternator according to customers' demand.
Gensets can be open type or soundproof (silent) type.
Gensets' Electric Performance
Gensets compliance with all main standards, such as: GB/T2820, ISO8528, IEC34, VDE0875-N
Prime output power: 7.2kw-1600 kw (8kva-1760kva)
Rated voltage: 400/230v, 440/254v, 220/127v, etc.
Phase/connecting method: 3 phase 4 wire/Y type connection
Rated frequency: 50/60 Hz
Rated speed: 1500/1800rpm
Excited type: Brushless, self excited or PMG
Insulation: Class H
Protection: IP21~IP23
Voltage regulation: AVR automatic control
Altitude above sea level: ≤1000 meters
Ambient air temperature: ≤40℃
Relative air humidity: ≤ 90%
Controller system
1. The diesel generator set powered by PERKINS engine offers the standard control panel, including volt meter, frequency meter, ampere meter, water temperature gauge, oil temperature gauge, oil pressure gauge, AMF control module, oil level indicator, emergency button, preheating button, battery voltage gauge, and hours running counter for protection and transferring.
2. It can be combined with an ATS electric control cabinet, including circuit breaker, LCD or LED auto controller, indicating lamp, transfer switch, etc. The automatic transfer switch (ATS) uses updated technology, which can be automatic control for on-off electricity, remote monitoring, automatic parallel operation, etc.
| Technical Data | |||||||||
| Gensets Type | Gensets Power(KW/KVA) | Engine Type | Engine Power/kw | Alternator(dynamotor) | |||||
| Rated Power | Standby Power | Rated Power | Standby Power | Scope Power Brushless | Stamford | Leroy Somer | Marathon | ||
| KW/KVA | KW/KVA | ||||||||
| SC-P10 | 7.2/9 | 8/10 | 403D-11G | 8.4/10.5 | 9.3/12 | SC-164B | PI044E | LSA42.2VS0/8 | GM-8.6-4 |
| SC-P15 | 10.4/13 | 11.2/14 | 403D-15G | 12.2/15 | 13.4/17 | SC-164C | PI044F | LSA42.2VS1/10 | GM-12-4 |
| SC-P22 | 16/20 | 17.6/22 | 404D-22G | 18.4/23 | 20.3/25 | SC-184E | PI044D | LSA42.2S5 | GM-16-4 |
| SC-P30 | 21/26 | 23/29 | 404D-22TG | 24.9/31 | 27.4/34 | SC-184F | PI044E | LSA42.2M7 | GM-20-4 |
| SC-P33 | 24/30 | 26.4/33 | 1103A-33G | 27.7/35 | 30.4/38 | SC-184G | PI144G | LSA42.2L9 | GM-24-4 |
| 1103C- 33G3 |
27.7/35 | 30.4/38 | SC-184G | LSA42.2L9 | GM-24-4 | ||||
| SC-P50 | 36/45 | 40/50 | 1103A- 33TG1 |
41.3/52 | 45.6/57 | SC-224C | UCI224D | LSA43.2S25 | GM-32-4 |
| 1103C- 33TG3 |
40.9/51 | 45.6/57 | SC-224C | LSA43.2S25 | GM-32-4 | ||||
| SC-P66 | 48/60 | 52.8/66 | 1103A- 33TG2 |
53.9/68 | 59.3/74 | SC-224E | UCI224E | LSA43.2M45 | MP-48-4 |
| 1104C- 44TG3 |
53/66 | 59/74 | SC-224E | LSA43.2M45 | MP-48-4 | ||||
| SC-P72 | 52/65 | 57.2/71.5 | 1104A- 44TG1 |
58.4/73 | 64.3/80 | SC-224F | UCI224F | LSA43.2M45 | MP-50-4 |
| SC-P88 | 64/80 | 70.4/88 | 1104C- 44TAG1 |
71.3/89 | 78.4/98 | SC-224G | UCI224G | LSA43.2L8 | MP-64-4 |
| 1104A- 44TG2 |
71.9/90 | 79.1/99 | SC-224G | LSA43.2L8 | MP-64-4 | ||||
| SC-P110 | 80/100 | 88/110 | 1104C- 44TAG2 |
89/111 | 97.9/122 | SC-274C | UCI274C | LSA44.2VS3 | MP-80-4 |
| SC-P150 | 108/135 | 120/150 | 1006TAG | 121/151 | 133.5/167 | SC-274E | UCI274E | LSA44.2S75 | MP-104-4 |
| 106C- E66TAG2 |
124/155 | 137.5/172 | SC-274E | LSA44.2S75 | MP-104-4 | ||||
| SC-P165 | 120/150 | 132/165 | 1006TAG2 | 129.3/162 | 143/179 | SC-274FS | UCI274F | LSA44.2M95 | MP-120-4 |
| 1106D- E66TAG3 |
129.3/162 | 143/179 | SC-274FS | LSA44.2M95 | MP-120-4 | ||||
| SC-P200 | 144/180 | 160/200 | 1106D- E66TAG4 |
158.8/198.5 | 175.9/220 | SC-274G | UCI274H | LSA46.2M3 | MP-160-4 |
| SC-P228 | 166/207.5 | 182/227.5 | 1306C- E87TAG3 |
180/225 | 199/249 | SC-274H | UCI274J | LSA46.2M4 | MP-160-4 |
| SC-P250 | 182/227.5 | 200/250 | 1306C- E87TAG4 |
198/247.5 | 217/27 | SC-274J | UCI274K | LSA46.2L6 | MP-180-4 |
| SC-P260 | 188/235 | 207/259 | 1306C- E87TAG5 |
204/255 | 224/280 | SC-274K | UCI274K | LSA46.2L6 | MP-200-4 |
| SC-P275 | 200/250 | 220/275 | 1306C- E87TAG6 |
217/271 | 239/299 | SC-C4C | UCD274K | LSA46.2L6 | MP-200-4 |
| SC-P350 | 240/300 | 280/350 | 2206C- E13TAG2 |
304/380 | 348/435 | SC-C4D | HCI444D | LSA46.2L9 | MP-240-4 |
| SC-P360 | 260/325 | 286/357.5 | 2206C- E13TAG2 |
304/380 | 348/435 | SC-C4ES | HCI444ES | LSA46.2VL12 | MP-260-4 |
| SC-P400 | 280/350 | 320/400 | 2206C- E13TAG2 |
304/380 | 348/435 | SC-C4E | HCI444FS | LSA47.2VS2 | MP-280-4 |
| SC-P450 | 320/400 | 360/450 | 2206C- E13TAG3 |
344/430 | 387/484 | SC-C4F | HCI444FS | LSA47.2S4 | MP-320-4 |
| SC-P500 | 364/455 | 400/500 | 2506C- E15TAG1 |
396/495 | 435/544 | SC-C5C | HCI544C | LSA47.2S5 | MP-350-4A/S |
| SC-P550 | 400/500 | 440/550 | 2506C-E15TAG2 | 435/544 | 478/597.5 | SC-C5D | HCI544D | LSA47.2M7 | MP-400-4A/S |
| SC-P660 | 480/600 | 528/660 | 2806A- E18TAG1A |
522/652.5 | 574/717.5 | SC-C5E | HCI544E | LSA47.2L9 | MP-480-4A/S |
| 2806A- E18TAG3 |
522/652.5 | 565/706 | SC-C5E | LSA47.2L9 | MP-480-4A/S | ||||
| SC-P700 | 520/650 | 560/700 | 2806A- E18TAG2 |
565/706 | 609/761 | SC-C5F | HCI544F | LSA49.1S4A | MX-500-4 |
| SC-P800 | 584/730 | 640/800 | 4006- 23TAG2A |
620/775 | 685/856 | SC-LV6B | LV634B | LSA49.1M6 | MX-600-4 |
| SC-P900 | 640/800 | 720/900 | 4006- 23TAG3A |
679/849 | 760/950 | SC-LV6C | HCI634G | LSA49.1M75 | MX-630-4 |
| SC-P1000 | 728/910 | 800/1000 | 4008TAG2A | 861/1076 | 947/1184 | SC-LV6D | HCI634H | LSA49.1L10 | MX-750-4 |
| SC-P1100 | 800/1000 | 880/1100 | 4008TAG2A | 861/1076 | 947/1183.4 | SC-LV6E | HCI634J | LSA50.2S4 | MX-850-4 |
| SC-P1375 | 1000/1250 | 1100/1375 | 4012- 46TWG2A |
1055/1319 | 1166/1457.5 | SC-LV6G | PI734A | LSA50.2M6 | MX-1030-4 |
| SC-P1500 | 1088/1360 | 1200/1500 | 4012- 46TWG3A |
1149/1436 | 1263/1579 | SC-P17B | PI734B | LSA50.2L7 | MX-1030-4 |
| SC-P1650 | 1200/1500 | 1320/1650 | 4012- 46TAG2A |
1267/1584 | 1396/1745 | SC-P17C | PI734C | LSA50.2L8 | MX-1240-4 |
| SC-P1820 | 1320/1650 | 1456/1820 | 4012- 46TAG3A |
1436/1795 | 1579/1974 | SC-P17D | PI734D | LSA50.2VL10 | MX-1350-4 |
| SC-P2000 | 1460/1825 | 1600/2000 | 4016TAG1A | 1537/1921 | 1690/2112.5 | SC-P17E | PI734E | LSA51.2S55 | MX-1540-4 |
| SC-P2200 | 1600/2000 | 1760/2200 | 4016TAG2A | 1715/2144 | 1886/2357.5 | SC-P17F | PI734F | LSA51.2L70 | MX-1540-4 |
As a specialized diesel generator set powered by PERKINS engine manufacturer based in China, we also provide diesel generator set powered by LOVOL engine, diesel generator set powered by CUMMINS engine, YD engine diesel generator, open frame diesel generator, and DEUTZ diesel generator, among others.